Skip to main content
NOTACHEMSHANGHAI · CHINA

Quality & compliance

Quality is recorded, not promised

Saying "reliable quality" costs nothing. A complete batch record costs something. So we put the verifiable part first: how lots are numbered, how long samples are retained, what a COA contains, how methods are validated, and what an audit will see.

100%
Batches retained
2 years
Standard retention from manufacture
4
Core COA results
1 day
Document response

Quality system

Six control points from goods-in to release

A system is worth what it can trace back to when something goes wrong — not the thickness of its manual. Six control points cover a batch from start to release.

01 Suppliers and raw materials

Approved supplier list for critical materials; lot number, COA and appearance checked on receipt, with full re-testing where required. Source changes go through change control — no ad-hoc substitution.

02 Lot numbers and batch records

Each batch carries its own lot number in the form product code–production date–sequence. Records are completed alongside production: charges, actual temperatures, timings, deviations and their handling.

03 In-process control

Critical steps have IPC points: reaction end-point by HPLC or TLC rather than a timer, with temperature, time and loss-on-drying monitored during crystallization and drying.

04 Finished goods testing

Tested against specification: assay, related substances, residual solvents, water and appearance as standard; ee added for chiral compounds. Failing batches are neither blended nor re-labelled for release.

05 Retention and stability

Every batch retained, two years as standard and longer for ongoing supply. Accelerated and long-term studies under ICH conditions can be run to support retest dates.

06 Deviations and changes

Deviations record facts, cause, impact and action. Changes are graded minor, major or critical; major changes to route, source or critical parameters require written client agreement.

Documentation

What you actually receive

Documents are not a freebie. Purchasing, quality and technical teams read different parts, so they are listed here by purpose.

COA — certificate of analysis

Ships with each batch, one per lot, stating lot number, test basis, results and conclusion.

  • Lot number and production date
  • Assay by HPLC (area normalisation or external standard)
  • Related substances (largest single and total)
  • Residual solvents per ICH Q3C class
  • Water by Karl Fischer
  • Appearance and physical tests

SDS — safety data sheet

GHS format, available in Chinese and English, with the full 16-section version on request.

  • Composition and identification
  • Hazard identification and classification
  • First aid and fire-fighting measures
  • Spill, storage and transport handling
  • Exposure control and personal protection

Methods and validation

Provided for method transfer or laboratory verification, with spectra and validation data.

  • HPLC related-substance method
  • Chiral method with ee calculation
  • GC residual solvent method
  • Validation report (specificity, linearity, accuracy, precision)

Specification and process description

Technical summaries for supplier qualification and internal technical review, available under NDA.

  • Product specification
  • Process route summary (not step-level)
  • Critical control point description
  • Packaging, storage and retest date

Standard documents (COA, SDS) within one business day; validation reports and process descriptions within three to five business days depending on scope.

Request documents

Analytics

Where the judgement comes from

All release data is generated on our own analytical platform, and spectra can accompany the COA. We do not release on the strength of a supplier statement alone.

HPLC
Assay, purity, related substances
Routine release
Chiral HPLC
Enantiomeric excess, chiral purity
Release for chiral compounds
GC / GC-MS
Residual solvents, volatiles
Controlled per ICH Q3C class
LC-MS
Mass confirmation, impurity assignment
Structure and impurity studies
NMR (400 MHz)
1H, 13C, 2D
Structural elucidation
Karl Fischer / melting point / optical rotation / residue on ignition
Routine physical chemistry
Selected per product specification

Equipment & capacity

Reactor matrix

Volumes span bench to commercial, with wetted materials chosen for corrosivity and metal sensitivity.

Volume
5 L / 50 L / 100 L / 500 L / 1,000 L / 5,000 L / 10,000 L
Wetted materials
Borosilicate glass · glass-lined steel · 316L stainless · Hastelloy C-276
Temperature
−78 °C to 200 °C
Pressure
Atmospheric to 5 MPa (hydrogenation vessels)
Agitation
Anchor, paddle, turbine, with gas sparger options
Work-up
Centrifugation, filtration, vacuum and freeze drying, milling and blending

Equipment data reflect partner plant configuration; the vessels available for a specific product are confirmed in writing during project assessment.

EHS

Safety and environment are not an appendix

Chemical process risk is concrete: heat, gas evolution, dust, waste solvent. This is what we actually do about it.

Reaction hazard assessment

Calorimetry and hazard identification before any new route or scale-up, establishing heat release rate, gas generation and the thermal runaway boundary before charging and quench are decided.

Hazardous chemistry protocols

Hydrogenation, cryogenic, anhydrous and strongly exothermic reactions carry dedicated procedures and emergency plans, operated by trained and authorised staff.

Waste management

Waste solvents segregated and consigned to licensed disposal; concentrated aqueous waste pre-treated rather than diluted and discharged.

Solvent substitution

Lower-toxicity alternatives evaluated during process development, reducing hazard at source rather than treating it downstream.

Occupational health

Local exhaust ventilation and personal protection for dusts and volatiles, with periodic health surveillance and environmental monitoring.

Certifications

A straight answer on certifications

This site does not display unverified certificates. Our R&D centre operates under a quality management system and partner plants operate under GMP systems; the regulatory status of a specific product, the certificates we can supply and audit arrangements are confirmed in writing. If you need ISO, GMP or other qualification documents for supplier approval, ask us directly — we provide what we actually hold, and nothing retrofitted.

Request quality documents

Need something specific?

Equipment lists, specifications, validation reports and audit support for prior projects are available on request. Tell us the purpose and you will get the right document.

Quality & compliance · Systems, analytics and documentation | NOTACHEM